Inductors
The solenoid is computed exactly, through Nagaoka’s coefficient, rather than by Wheeler’s formula, which is good to a percent and only for coils that are not too short. Besides the inductance you get Q, the self-resonance and the length of wire: without those a number in microhenries says little.
What you get
| Inductance | 299 nH |
|---|---|
| Reactance at the frequency | 13.2 Ω |
| Quality factor | 64 (upper bound) |
| Resistance: DC | 0.2074 Ω |
| Resistance: at the frequency | 0.2074 Ω |
| Wire length | 0.126 m |
| Inner size | 3.40 mm |
| Window fill | 49 % |
a planar coil’s capacitance to ground and its Q depend on what lies underneath: over a solid ground plane the inductance drops and the losses rise. The model does not know about that