RF·Tools

Inductors

The solenoid is computed exactly, through Nagaoka’s coefficient, rather than by Wheeler’s formula, which is good to a percent and only for coils that are not too short. Besides the inductance you get Q, the self-resonance and the length of wire: without those a number in microhenries says little.

Type

What you get

Inductance299 nH
Reactance at the frequency13.2 Ω
Quality factor64 (upper bound)
Resistance: DC0.2074 Ω
Resistance: at the frequency0.2074 Ω
Wire length0.126 m
Inner size3.40 mm
Window fill49 %
a planar coil’s capacitance to ground and its Q depend on what lies underneath: over a solid ground plane the inductance drops and the losses rise. The model does not know about that