RF·Tools

Inductors

The solenoid is computed exactly, through Nagaoka’s coefficient, rather than by Wheeler’s formula, which is good to a percent and only for coils that are not too short. Besides the inductance you get Q, the self-resonance and the length of wire: without those a number in microhenries says little.

Type

Leave “solve for turns” empty and what you entered is analysed. Fill in an inductance and you get a fractional turn count: rounding it off is the tuning.

What you get

Inductance48.3 µH
Reactance at the frequency2126.2 Ω
Quality factorset by the core
Resistance: DC0.0039 Ω
Resistance: at the frequency0.0392 Ω
Wire length0.178 m
Window fill45 %
on a ferrite coil the Q is set by the core, not by the wire: for choke materials it can be in the single digits at the working frequency. The wire alone would give 54198, which is why the number is not shown — look up the μ″ curves in the core datasheet
ferrite permeability depends on frequency, on field and on the batch: twenty percent spread is normal. If the maker publishes A_L, use that instead
the wire is thicker than six skin depths (0.025 mm at this frequency): the middle does nothing, and Q does not grow the way you would like
Q is computed from the skin effect alone. The proximity effect — adjacent turns pushing the current out of each other — is not in the model, and it is expensive: on a close-wound coil the real Q comes out one and a half to three times lower. Treat the figure as an upper bound