RF·Tools

BPGE-252R+

Mini-Circuits · Band-pass Other

S-parameters

Drag across the plot to zoom in; double-click or Esc returns the full range. The tooltip reads out every trace at the cursor frequency.

What the data says

Loss across 2.218 GHz…2.694 GHz1.23…4.23 дБ
−3 dB band (from the data)2.218 GHz…2.694 GHz
Lowest loss1.23 dB at 2.384 GHz
Return loss across the whole −3 dB bandno worse than 4.0 dB
Rejection 1.109 GHz…1.775 GHz20.9 dB (datasheet: ≥20 dB)
Rejection 3.368 GHz…5.388 GHz32.7 dB (datasheet: ≥32 dB)
Data range1 GHz…6 GHz, 2501 points

Rejection per datasheet

BandAt leastNote
1.109 GHz…1.775 GHz 20 dB из S-параметров
3.368 GHz…5.388 GHz 32 dB из S-параметров

Data sets

SourceRangePointsFile
Mini-Circuits, +25 °C
из https://www.minicircuits.com/pages/s-params/BPGE-252R%2B_S2P.zip
1 GHz…6 GHz 2501 at the source

Parameters

Band (3dB)2.218 GHz…2.694 GHz
Centre2.445 GHz
Fractional BW19.5 %
Insertion losstyp. 1.39 / max. 2.23 дБ
Ripple1.00 дБ
Return loss≥ 8.7 дБ
Impedance50 Ω
PackageGE0805C-3
Mountingnot specified
Temperature—
StatusUnknown

Data source: S-параметры Mini-Circuits, https://www.minicircuits.com/pages/s-params/BPGE-252R%2B_S2P.zip

Similar

Compare all responses