Transmission lines
Impedance from the dimensions, or a dimension for the impedance, plus what usually takes longest to find: velocity factor, delay, capacitance per metre and loss at the frequency you care about. The loss is split into copper and dielectric — they grow differently, and you see at once which one decides your case.
Cross-section
Loss over frequency
Decibels per metre. Copper loss grows as the square root of frequency, dielectric loss linearly: where the curves cross is where it stops being one and starts being the other.
What you get
| Characteristic impedance | 47.12 Ω |
|---|---|
| εeff | 1.709 |
| Velocity factor | 0.765 |
| Delay | 4.36 ns/m |
| Wavelength | 1.58 m |
| λ/4 | 0.395 m |
| Capacitance per metre | 92.5 pF/m |
| Inductance per metre | 205 nH/m |
| Loss | 0.273 dB/m |
| of which copper | 0.269 dB/m |
| of which dielectric | 0.004 dB/m |
| Over 1 m | 0.27 dB |