Transmission lines
Impedance from the dimensions, or a dimension for the impedance, plus what usually takes longest to find: velocity factor, delay, capacitance per metre and loss at the frequency you care about. The loss is split into copper and dielectric — they grow differently, and you see at once which one decides your case.
Cross-section
Loss over frequency
Decibels per metre. Copper loss grows as the square root of frequency, dielectric loss linearly: where the curves cross is where it stops being one and starts being the other.
What you get
| Characteristic impedance | 67.25 Ω |
|---|---|
| εeff | 1.857 |
| Velocity factor | 0.734 |
| Delay | 4.55 ns/m |
| Wavelength | 1.52 m |
| λ/4 | 0.379 m |
| Capacitance per metre | 67.6 pF/m |
| Inductance per metre | 306 nH/m |
| Loss | 0.137 dB/m |
| of which copper | 0.133 dB/m |
| of which dielectric | 0.004 dB/m |
| Over 1 m | 0.14 dB |