Reactive matching
A complex load is brought to the source with two or three reactances. The values are computed exactly and then snapped to a standard series — the chart shows where that moved the null. An L section gives you no choice of Q: the impedance ratio sets it. Pi and T let you pick it, and that is bandwidth traded for transformation, one for one.
The order runs from source to load; ∥ means shunt. Every variant matches equally well — what differs is whether the values are buyable and what the network does outside the band.
Circuit
Match over frequency
One curve uses the series values, the other the exact ones. The dip is the match.
Smith chart
The path runs from the load to the source: a series element moves along a constant-R circle, a shunt one along a constant-G circle. The cross is the target, the conjugate match. The second curve is how the input Z wanders with frequency.
Values
| Element | Connection | Exact | Series | Reactance, Ω |
|---|---|---|---|---|
| L1 | series | 70.3 nH | 68 nH | 44.2 |
| C1 | shunt | 44.4 pF | 43 pF | -35.8 |
What you get
| Matching | 26.5 dB |
|---|---|
| Loss in the network | 0.10 dB |
| Network Q | 1.00 |
| −10 dB bandwidth | 71.2…128 MHz (57 %) |
| Load | 25.0+40.0j Ω |
| Source | 50.0 Ω |
The match and the loss are computed from the series values and the inductor Q — this is what the real thing will do.